Electrical Steel Coil

Send Inquiry
Electrical Steel Coil
Details
Electrical steel coil (silicon steel) is a soft magnetic iron-silicon alloy engineered for electromagnetic energy conversion. The addition of silicon increases electrical resistivity, reduces eddy current losses, and lowers magnetostriction.
Category
Steel Coil & Strip
Share to
Description

Electrical steel coil (silicon steel) is a soft magnetic iron-silicon alloy engineered for electromagnetic energy conversion. The addition of silicon increases electrical resistivity, reduces eddy current losses, and lowers magnetostriction.


Supply options cover non-oriented (NGO) and grain-oriented (GO) configurations. Non-oriented grades provide isotropic magnetic properties across all directions, making them suited for rotating equipment. Grain-oriented grades feature an anisotropic Goss texture, optimized for single-direction magnetic flux in stationary transformers.


Coils are supplied in fully processed condition, slit to specified widths, with insulation coatings tailored to downstream stamping, annealing, and assembly operations.

 

Key Product Characteristics

 

Low Core Loss (W/kg): Specific total loss limits at 1.5T/50Hz (NGO) or 1.7T/50Hz (GO) control heat generation in laminated cores.


High Magnetic Permeability: Achieves rapid magnetization at low magnetic field strengths (H), lowering excitation current requirements.


Controlled Stamping Properties: Burr heights maintained under 0.02 mm during high-speed lamination blanking to protect inter-lamination insulation.


High Stacking Factor (95% to 97% or higher): Tight thickness tolerances and minimal crown maximize active iron volume within core slots.


Insulation Coating Integrity: Inorganic and semi-organic coatings withstand continuous temperatures up to 800 degrees C (stress-relief annealing compatible) without flaking.

 

Technical Specifications

 

Parameter

Non-Oriented (NGO)

Grain-Oriented (GO)

Nominal Thickness

0.35 mm, 0.50 mm, 0.65 mm

0.23 mm, 0.27 mm, 0.30 mm, 0.35 mm

Thickness Tolerance

+/- 0.015 mm to +/- 0.025 mm

+/- 0.010 mm to +/- 0.020 mm

Coil Width Range

100 mm - 1250 mm

100 mm - 1000 mm

Slitting Width Tolerance

+/- 0.10 mm

+/- 0.10 mm

Inner Diameter (ID)

508 mm / 610 mm

508 mm / 610 mm

Silicon Content

0.5% - 3.2% wt

2.9% - 3.4% wt

Density

7.60 - 7.80 g/cm3

7.65 g/cm3

Specific Core Loss (P1.5/50)

2.30 - 6.50 W/kg

N/A

Specific Core Loss (P1.7/50)

N/A

0.85 - 1.30 W/kg

Minimum Induction (B50 / B8)

1.60 - 1.73 T (B50)

1.80 - 1.93 T (B8)

 

Grades & Standards

 

Material conforms to IEC, ASTM, EN, and AISI specifications. Mill test certificates (MTC) confirm compliance per EN 10204 3.1.

Non-Oriented Grades (NGO)

  • IEC 60404-8-4 / EN 10106: M250-50A, M270-50A, M330-50A, M400-50A, M470-50A, M600-50A
  • ASTM A677: 47F190, 47F205, 47F230, 47F280, 47F450
  • AISI Equivalents: M-19, M-22, M-27, M-36, M-43, M-45
 

Grain-Oriented Grades (GO)

  • IEC 60404-8-7 / EN 10107: M095-23S, M103-27S, M111-30S, M120-35S (Standard); M080-23H, M085-27H (High Permeability / Hi-B)
  • ASTM A876: 23G045, 27G051, 30G058
 

Surface & Processing Options

 

Insulation Coatings (IEC 60404-1-1 / C-Type)

  • C-3 (Organic Thin Film): Improves punchability and die life; suitable for low-temperature application.
  • C-5 (Semi-Organic Chromate-Free): General-purpose core coating providing corrosion resistance, weldability, and burn-proof performance.
  • C-6 (Inorganic / High Temperature): Formulated for cores undergoing post-stamping stress-relief annealing at 750 to 800 degrees C in neutral or reducing atmospheres.


Slitting & Edges

  • Edge Condition: Mill edge or precision slit edge.
  • Slitting Burr: Controlled under 0.02 mm across all widths.
  • Camber: 1.0 mm or less per 2000 mm gauge length.

 

Applications

 

Electric Motors: Stators and rotors for industrial induction motors, HVAC compressor units, and EV traction motors (NGO grades: M250-50A to M400-50A).


Power & Distribution Transformers: Step-up, step-down, and dry-type distribution core laminations (GO grades: M095-23S, M103-27S, Hi-B).


Generators: Hydro, wind, and industrial power generation stators requiring low isotropic loss.


Small Transformers & Reactors: EI laminations, current transformers (CTs), ballasts, and UPS inductors.

 

Quality Control & Inspection

 

Testing protocols follow ASTM A343 and IEC 60404-2 standards. Each production heat is sampled and verified prior to dispatch.


Inspection Steps:

  • Step 1: Raw Material Heat Verification
  • Step 2: Epstein Frame Core Loss Testing
  • Step 3: Continuous Laser Crown & Thickness Measurement
  • Step 4: Franklin Test for Surface Coating Insulation
  • Step 5: Issue EN 10204 3.1 Mill Test Certificate (MTC)


Testing Capabilities:

  • Magnetic Testing: Epstein Frame and Single Sheet Tester (SST) for specific core loss (W/kg) and flux density (T).
  • Dimensional Inspection: Continuous laser micrometers track thickness profile, crown, and edge drop across coil length.
  • Insulation Resistance: Franklin tester (IEC 60404-2) measures surface insulation resistance before and after thermal exposure.
  • Mechanical & Physical: Tensile strength, yield point, elongation, bend test, and stacking factor measurement.

 

Supply & Customization Options

 

Slitting Services: Narrow strip slitting down to 15 mm minimum width.


Coil Weight Management: Standard eye-to-sky or eye-to-wall coils from 2.0 to 10.0 metric tons; baby coils available upon request.


Packaging: VCI anti-rust paper wrapper, HDPE plastic film, edge protectors, steel strapping, export-worthy wooden pallets or skids.


Moisture Protection: Desiccant packs included within sealed barrier bags for sea freight transit (compliant with ISPM-15).

 

What Buyers Should Provide for a Quote

 

To receive a formal commercial proposal within 24 hours, supply the following parameters:

01/

Grade / Standard Specification: (E.g., M270-50A per EN 10106 or ASTM 47F205)

02/

Coil Dimensions: Nominal thickness (mm) x width (mm)

03/

Core Loss / Induction Limits: Specific loss target if tighter than standard

04/

Coating Type: C-3, C-5, or C-6 (indicate if post-blanking stress-relief annealing is required)

05/

Quantity & Delivery Terms: Metric tonnage, destination port, and preferred Incoterms (FOB, CFR, CIF)

06/

Packaging Requirements: Max coil weight limit, eye orientation (vertical vs. horizontal)

FAQ

 

Q: What is the primary operational difference between Non-Oriented (NGO) and Grain-Oriented (GO) electrical steel?

A: NGO steel has uniform magnetic properties in all directions (isotropic), making it essential for rotating machinery like electric motors where the magnetic field direction constantly changes. GO steel is processed to align magnetic grains in the rolling direction (anisotropic), reducing energy loss in stationary equipment like transformer cores.

Q: Does stress-relief annealing damage the insulation coating?

A: Not if the correct coating is specified. C-6 inorganic coatings are engineered to withstand stress-relief annealing at 750 to 800 degrees C without loss of insulation or adhesion. C-3 and standard C-5 coatings are not designed for high-temperature annealing.

Q: How do you prevent edge rust during oceanic transit?

A: Coils are treated with corrosion inhibitors, wrapped in VCI paper and heavy-duty plastic film, fitted with metallic inner and outer edge protectors, and secured on wooden skids with desiccant packs sealed inside.

Hot Tags: electrical steel coil, China electrical steel coil manufacturers, suppliers, factory

Send Inquiry